Data last updated: November 19, 2026 (America/New_York). Sources: CMS Provider Data Catalog, Virginia DSS licensed-care search, and the official DARS Auxiliary Grant list. Methodology and pull dates.
Assisted living facility · Fairfax CountyGreenspring Village, Inc.
7470 Spring Village Dr, SPRINGFIELD, VA 22150 · 703-923-4649
Official record at a glance
DSS license 24789Source: Virginia Department of Social Services licensed-care search, pulled November 19, 2026 (America/New_York). Inspection results are the state’s, not ours.
This facility was not matched to the official DARS Auxiliary Grant list used in this pull (October 2026). That does not prove it is ineligible or eligible; it means it was not on that list or could not be matched conservatively. Confirm with DARS and the facility.
Official inspection table
| Inspection date(s) | Complaint related | Violations cited | Official record |
|---|---|---|---|
| 08/05/2026 | YES | Y | Official DSS inspection |
| 08/05/2026 | not reported | N | Official DSS inspection |
| 08/05/2026 | YES | N | Official DSS inspection |
| 08/05/2026 | YES | Y | Official DSS inspection |
| 06/11/2026 | not reported | Y | Official DSS inspection |
| 06/11/2026 | not reported | N | Official DSS inspection |
| 04/01/2026 | not reported | N | Official DSS inspection |
| 04/01/2026 | not reported | Y | Official DSS inspection |
| 02/17/2026 | not reported | Y | Official DSS inspection |
| 01/29/2026 | YES | Y | Official DSS inspection |
| 01/20/2026 | not reported | N | Official DSS inspection |
| 12/01/2025 | YES | N | Official DSS inspection |
| 12/01/2025 & 12/02/2025 | not reported | Y | Official DSS inspection |
| 10/25/2025 | not reported | N | Official DSS inspection |
| 08/01/2025 | YES | Y | Official DSS inspection |
| 08/01/2025 | YES | Y | Official DSS inspection |
| 08/01/2025 | not reported | Y | Official DSS inspection |
| 10/25/2024 | not reported | N | Official DSS inspection |
| 10/16/2024 | not reported | N | Official DSS inspection |
| 08/12 - 8/13/2024 | not reported | Y | Official DSS inspection |
| 08/12/2024 | YES | N | Official DSS inspection |
| 11/29/2023 | not reported | N | Official DSS inspection |
| 10/17/2023 | YES | N | Official DSS inspection |
| 12/16/2022 | not reported | Y | Official DSS inspection |
| 08/11/2022 | not reported | N | Official DSS inspection |
| 12/23/2021, 01/06/2022, 01/2 | not reported | Y | Official DSS inspection |
| 02/22/2021 | YES | Y | Official DSS inspection |
Official violation standards from the most recent inspection that cited violations
- 22VAC40-73-(6)-560-EBased on observation, the facility failed to ensure that resident records were stored in a locked area. Evidence: 1. During a tour of the facility on 8/5/2026, two (2) LI’s observed the door to the first floor right wing of Rose Court “charting” office open with no staff inside. 2. Resident 1,2,3,4,5 and 6’s full resident records were observed on the desk. 3. Staff 1 and Staff 2 acknowledged the resident records were not secured and locked. Plan of Correction: 1.The resident records identified during the inspection were immediately secured and the charting office door was locked. Confidential resident information was protected immediately in the RC1 Nursing station. Education was provided to all Care team members on the Rose Court 1 neighborhood on Wednesday August 12th,2026 on the importance of securing resident PHI and keeping the nursing station door closed. 2. A 100% audit of all nursing stations which store resident records within Assisted Living and Memory care will be completed to ensure resident records are secured when not actively in use. Any unsecured records identified during the audit will be immediately secured. 3. All Nursing and Care associates will be educated by Assisted Living Manager or designee regarding securing Nursing station doors. 4.The Administrator or designee will conduct random weekly audits of all nursing stations weekly for four (4) weeks and monthly for two (2) months to ensure resident records remain secured and stored appropriately. Any discrepancies identified will be immediately corrected and findings will be reviewed in QAPI for further recommendations or additional monitoring.
- 22VAC40-73-(9)-990-ABased on record review and staff interview, the facility failed to ensure that assisted living facility should have a written plan for resident emergencies. Evidence: 1. The facility plan for resident emergencies was requested for review. A plan for mental health emergencies was missing. 2. During an interview with Staff 1 on 08/05/2026, staff 1 acknowledged they could not provide written procedures for handling mental health emergencies. Plan of Correction: 1: The facility will update written procedures addressing resident mental health emergencies and incorporate the procedures into the Emergency Preparedness Plan to ensure staff have guidance for responding appropriately to mental health emergencies. 2.A 100% audit of all Emergency Preparedness Plan components, emergency response procedures, and required policies related to Mental Health emergencies will be completed to ensure all required emergency response elements are included. 3. The Emergency Preparedness Plan was revised to include mental health emergency procedures. Education was provided to Assisted Living leadership, wellness staff, and direct care staff regarding recognition, response, notification, intervention, and documentation requirements related to mental health emergencies.
- 22VAC40-73-(9)-960-BBased on observation and interview, the facility failed to ensure the fire and emergency evacuation drawings include all required components. Evidence: 1. During the inspection tour on 8/5/2026, the posted evacuation plans on the second floor in the facility did not include secondary escape routes, area of refuge, and fire alarm boxes. 2. Staff 1 acknowledged the drawings did not include all required components. Plan of Correction: 1. The facility reviewed the evacuation diagrams cited during the inspection and initiated revisions to include all required components, including secondary escape routes, areas of refuge, and fire alarm box locations. 2.A 100% audit of all posted evacuation diagrams throughout the Assisted Living community will be completed by General services Director or designee to verify inclusion of all required emergency evacuation information to include secondary escape routes, area of refuge and fire alarm boxes. Any incomplete diagrams identified during the audit will be revised and replaced. 3.Updated evacuation diagrams will be developed and posted on the second floor.
- 22VAC40-73-(8)-940-ABased on record review and staff interview, the facility failed to ensure that an assisted living facility should comply with the Virginia Statewide Fire Prevention Code (13VAC5-51) as determined by at least an annual inspection by the appropriate fire official. Reports of the inspections should be retained at the facility for at least two years. Evidence: 1. Upon arrival on 08/05/2026, two (2) LI’s observed the posted annual fire inspection expired on 7/31/2026. 2. Staff 1 acknowledged the facility's posted annual fire inspection expired on 7/31/2026 and that they are waiting for the inspection to be conducted. 3. On 08/07/2026, LI called and spoke with Collateral Contact 1 in which they confirmed that facility did not call and schedule the annual fire inspection. Plan of Correction: 1.The facility immediately contacted the appropriate fire official and requested scheduling of the required annual fire inspection on August 5th. Upon completion, the current inspection documentation was posted as required. The Fire safety Inspection was completed on Friday 8/7/26. The updated Fire Inspection Permit was sent to VDSS. 2. A Fire safety inspection tracking system will be implemented to monitor fire Inspection permit and expiration date.
- 22VAC40-73-(6)-530-BBased on observation and interview, the facility failed to ensure doors leading to the outside not be locked from the inside or secured from the inside in any manner that amounts to a lock. Evidence: 1. During the course of the inspection on 8/5/2026, two (2) LI’s observed exterior exit doors throughout the left wing first floor locked with a numerical keypad lock next to the door. LI’s observed a numerical riddle with numbers embedded that would unlock the door. These doors are not located in the safe, secure environment. 2. Staff 1 confirmed the numerical keypad was required to open the exit doors on the assisted living areas of the facility. Plan of Correction: The identified Facility’s designated emergency exits locked with a keypad have had the code posted to allow for free egress of residents that are physically and cognitively able to navigate/ unlock the door using the code. Residents that cannot safely access, safely navigate cognitively, or are at significant risk for injury or death if navigating without assistance will have free egress in case of an emergency. The doors identified are emergency exits only and not intended for regular passage. Residents are free to move about the facility through all elevators and by way of the main entrance. In addition, 22VAC40-73-530 specifically calls out “doors leading to the outside.” All outside leading doors are currently unlocked. In addition, section 18.2.2.2.5.2 of NFPA 101 2012 & 2018 allows for “door locking arrangements… where patient special needs require specialized protective measures for their safety…” To put such measures in place, the following must be met; 1. Staff can readily unlock doors at all times in accordance with 19.2.2.2.6. 2. A total (complete) smoke detection system is provided throughout the locked space in accordance with 9.6.2.9, or locked doors can be remotely unlocked at an approved, constantly attended location within the locked space. 3. The building is protected throughout by an approved, supervised automatic sprinkler system in accordance with 19.3.5.1. 4. The locks are electrical locks that fail safely so as to release upon loss of power to the device. 5. The locks release by independent activation of each of the following: (b) Activation of the smoke detection system required by 19.2.2.2.5.2(a) (b) Waterflow in the automatic sprinkler system required by 19.2.2.2.5.2(3). As our Executive Director noted, our Facility has a mix of residents with varying physical and mental capabilities. Many of our residents may lack capacity or have mobility issues causing extensive safety concerns if those residents gained access to an emergency-only exit unassisted, outside of an emergent situation. § 18.2.2.2.5.2 does not require that all residents meet a particular clinical threshold. Rather, this section mentions door locking “…where patient needs require specialized protective measures for their safety.” The section identifies pediatric, maternity and emergency departments as examples of where patients might have a special need that would justify door locking. This section also does not indicate a requirement that there is no less restrictive measure available prior to instituting the designated safety measure. Given the vulnerability of the population we serve and seek to protect, the Facility has elected to put these permitted safeguards in place to meet the needs of many of our residents, as our residents’ safety is central to our operations. In placing the allowed door locking arrangements, the Facility has diligently complied with applicable Life Safety Codes. In an emergent situation, staff are readily able to unlock doors at all times by facility staff at the designated panic buttons. The Facility has in place a complete smoke detection system included throughout the locked space. In addition, locked doors are able to be remotely unlocked by facility staff at the designated panic buttons. The building operates a supervised automatic sprinkler system. All locks on the doors in question are electrical and therefore, upon loss of power, activation of smoke detection system or automatic sprinkler, all doors will be automatically unlocked. (The submitted plan of correction exceeds the maximum allotted space. Please reach out to the department for the full plan of correction) Show Raw API Response { "facility": { "licenseId": 24789, "licensed": true, "facilityName": "Greenspring Village, Inc.", "address": { "streetNumber": "7470", "addressLine1": "Spring Village Dr", "city": "SPRINGFIELD", "state": "VA", "zipCode": "22150", "countyFipsCode": "059", "additionalProperties": [] }, "phoneNumber": "703-923-4649", "facilityType": "Assisted Living Facility", "additionalProperties": [] }, "inspector": { "person": { "firstName": "Alexandra", "lastName": "Roberts", "additionalProperties": [] }, "phone": "(804) 845-6956", "additionalProperties": [] }, "inspectionDates": "08\/05\/2026", "complaintRelated": "YES", "areasReviewed": { "areasReviewedList": [ "22VAC40-73-(4) STAFFING AND SUPERVISION\n22VAC40-73-(8) BUILDINGS AND GROUND\n22VAC40-73-(9) EMERGENCY PREPAREDNESS\n22VAC40-80-(G7) COMPLAINT INVESTIGATION" ], "additionalProperties": [] }, "technicalAssistanceList": [ "22VAC40-73-560" ], "commentsList": [ "Type of inspection: Complaint\nDate(s) of inspection and time the licensing inspector was on-site at the facility for each day of the inspection: 8\/5\/2026\n9am \u2013 5pm\nThe Acknowledgement of Inspection form was signed and left at the facility for each date of the inspection.\nA complaint was received by VDSS Division of Licensing on 6\/16\/2026 regarding allegations in the area(s) of: Staffing and Supervision and Buildings and Grounds.\nNumber of residents present at the facility at the beginning of the inspection: 216\nThe licensing inspector completed a tour of the physical plant that included the building and grounds of the facility.\nNumber of resident records reviewed: 6 - Partial\nNumber of staff records reviewed: 1\nNumber of interviews conducted with residents: 1\nNumber of interviews conducted with staff: 4\nObservations by licensing inspector: Staff and residents observed moving throughout the building.\nAdditional Comments\/Discussion:\nAn exit meeting will be conducted to review the inspection findings.\nThe evidence gathered during the investigation did not support the allegation(s) of non-compliance with standard(s) or law. However, violation(s) not related to the complaint(s) but identified during the course of the investigation can be found on the violation notice. The licensee has the opportunity to submit a plan of correction to indicate how the cited violation(s) will be addressed in order to return the facility to compliance and maintain future compliance with applicable standard(s) or law.\nIf the licensee wishes to provide a plan of correction: (i) type the plan on a separate Word document, (ii) identify the standard violation number being addressed, (iii) include the date the violation will be corrected, (IV) do not include any names or confidential information, and (V) return to the licensing inspector by email within five (5) business days of the exit interview. Your plan of correction must contain: 1) steps to correct the noncompliance with the standard(s), 2) measures to prevent the noncompliance from occurring again; and 3) person(s) responsible for implementing each step and\/or monitoring any preventive measure(s).\nCompliance with all applicable regulations and law shall be maintained and any areas of noncompliance must be corrected.\nWithin 15 calendar days of your receipt of these inspection findings (inspection summary, violation notice, and supplemental information), you may request a review and discussion of these findings with the inspector's immediate supervisor. To make a request for review and discussion, you must contact the licensing supervisor at the regional licensing office that serves your geographical area. Refer to General Procedures and Information for Licensure, 22VAC40-80-260-B for information on requesting a problem solving conference.\nRegardless of whether a supervisory review has been requested, the results of the inspection will be posted to the DSS public website within 5 business days of your receipt of the Inspection Summary and\/ or Violation Notice.\nThe department's inspection findings are subject to public disclosure.\nPlease Note: A copy of the findings of the most recent inspection are required to be posted on the premises of the facility.\nFor more information about the VDSS Licensing Programs, please visit: www.dss.virginia.gov\nShould you have any questions, please contact Alexandra Roberts, Licensing Inspector at (804) 845-6956 or by email at Alexandra.N.Roberts@dss.virginia.gov" ], "violationsList": [ { "standardNumber": "22VAC40-73-(6)-560-E", "description": "Based on observation, the facility failed to ensure that resident records were stored in a locked area.\nEvidence:\n1. During a tour of the facility on 8\/5\/2026, two (2) LI\u2019s observed the door to the first floor right wing of Rose Court \u201ccharting\u201d office open with no staff inside.\n2. Resident 1,2,3,4,5 and 6\u2019s full resident records were observed on the desk.\n3. Staff 1 and Staff 2 acknowledged the resident records were not secured and locked.", "planOfCorrectionList": [ { "planOfCorrectionText": "1.The resident records identified during the inspection were immediately secured and the charting office door was locked. Confidential resident information was protected immediately in the RC1 Nursing station. Education was provided to all Care team members on the Rose Court 1 neighborhood on Wednesday August 12th,2026 on the importance of securing resident PHI and keeping the nursing station door closed. \n2. A 100% audit of all nursing stations which store resident records within Assisted Living and Memory care will be completed to ensure resident records are secured when not actively in use. Any unsecured records identified during the audit will be immediately secured. \n3. All Nursing and Care associates will be educated by Assisted Living Manager or designee regarding securing Nursing station doors.\n4.The Administrator or designee will conduct random weekly audits of all nursing stations weekly for four (4) weeks and monthly for two (2) months to ensure resident records remain secured and stored appropriately. Any discrepancies identified will be immediately corrected and findings will be reviewed in QAPI for further recommendations or additional monitoring.", "planOfCorrectionHoverText": "***UKNONWN HOVER TEXT SOURCE ****", "additionalProperties": [] } ], "additionalProperties": [], "licenseId": 24789 }, { "standardNumber": "22VAC40-73-(9)-990-A", "description": "Based on record review and staff interview, the facility failed to ensure that assisted living facility should have a written plan for resident emergencies.\nEvidence:\n1. The facility plan for resident emergencies was requested for review. A plan for mental health emergencies was missing.\n2. During an interview with Staff 1 on 08\/05\/2026, staff 1 acknowledged they could not provide written procedures for handling mental health emergencies.", "planOfCorrectionList": [ { "planOfCorrectionText": "1: The facility will update written procedures addressing resident mental health emergencies and incorporate the procedures into the Emergency Preparedness Plan to ensure staff have guidance for responding appropriately to mental health emergencies. \n2.A 100% audit of all Emergency Preparedness Plan components, emergency response procedures, and required policies related to Mental Health emergencies will be completed to ensure all required emergency response elements are included. \n3. The Emergency Preparedness Plan was revised to include mental health emergency procedures. Education was provided to Assisted Living leadership, wellness staff, and direct care staff regarding recognition, response, notification, intervention, and documentation requirements related to mental health emergencies.", "planOfCorrectionHoverText": "***UKNONWN HOVER TEXT SOURCE ****", "additionalProperties": [] } ], "additionalProperties": [], "licenseId": 24789 }, { "standardNumber": "22VAC40-73-(9)-960-B", "description": "Based on observation and interview, the facility failed to ensure the fire and emergency evacuation drawings include all required components.\nEvidence:\n1. During the inspection tour on 8\/5\/2026, the posted evacuation plans on the second floor in the facility did not include secondary escape routes, area of refuge, and fire alarm boxes.\n2. Staff 1 acknowledged the drawings did not include all required components.", "planOfCorrectionList": [ { "planOfCorrectionText": "1. The facility reviewed the evacuation diagrams cited during the inspection and initiated revisions to include all required components, including secondary escape routes, areas of refuge, and fire alarm box locations. \n2.A 100% audit of all posted evacuation diagrams throughout the Assisted Living community will be completed by General services Director or designee to verify inclusion of all required emergency evacuation information to include secondary escape routes, area of refuge and fire alarm boxes. Any incomplete diagrams identified during the audit will be revised and replaced. \n3.Updated evacuation diagrams will be developed and posted on the second floor.", "planOfCorrectionHoverText": "***UKNONWN HOVER TEXT SOURCE ****", "additionalProperties": [] } ], "additionalProperties": [], "licenseId": 24789 }, { "standardNumber": "22VAC40-73-(8)-940-A", "description": "Based on record review and staff interview, the facility failed to ensure that an assisted living facility should comply with the Virginia Statewide Fire Prevention Code (13VAC5-51) as determined by at least an annual inspection by the appropriate fire official. Reports of the inspections should be retained at the facility for at least two years.\nEvidence:\n1. Upon arrival on 08\/05\/2026, two (2) LI\u2019s observed the posted annual fire inspection expired on 7\/31\/2026.\n2. Staff 1 acknowledged the facility's posted annual fire inspection expired on 7\/31\/2026 and that they are waiting for the inspection to be conducted.\n3. On 08\/07\/2026, LI called and spoke with Collateral Contact 1 in which they confirmed that facility did not call and schedule the annual fire inspection.", "planOfCorrectionList": [ { "planOfCorrectionText": "1.The facility immediately contacted the appropriate fire official and requested scheduling of the required annual fire inspection on August 5th. Upon completion, the current inspection documentation was posted as required. The Fire safety Inspection was completed on Friday 8\/7\/26. The updated Fire Inspection Permit was sent to VDSS.\n2. A Fire safety inspection tracking system will be implemented to monitor fire Inspection permit and expiration date.", "planOfCorrectionHoverText": "***UKNONWN HOVER TEXT SOURCE ****", "additionalProperties": [] } ], "additionalProperties": [], "licenseId": 24789 }, { "standardNumber": "22VAC40-73-(6)-530-B", "description": "Based on observation and interview, the facility failed to ensure doors leading to the outside not be locked from the inside or secured from the inside in any manner that amounts to a lock.\nEvidence:\n1. During the course of the inspection on 8\/5\/2026, two (2) LI\u2019s observed exterior exit doors throughout the left wing first floor locked with a numerical keypad lock next to the door. LI\u2019s observed a numerical riddle with numbers embedded that would unlock the door. These doors are not located in the safe, secure environment.\n2. Staff 1 confirmed the numerical keypad was required to open the exit doors on the assisted living areas of the facility.", "planOfCorrectionList": [ { "planOfCorrectionText": "The identified Facility\u2019s designated emergency exits locked with a keypad have had the code posted to allow for free egress of residents that are physically and cognitively able to navigate\/ unlock the door using the code. Residents that cannot safely access, safely navigate cognitively, or are at significant risk for injury or death if navigating without assistance will have free egress in case of an emergency. \nThe doors identified are emergency exits only and not intended for regular passage. Residents are free to move about the facility through all elevators and by way of the main entrance. In addition, 22VAC40-73-530 specifically calls out \u201cdoors leading to the outside.\u201d All outside leading doors are currently unlocked. \nIn addition, section 18.2.2.2.5.2 of NFPA 101 2012 & 2018 allows for \u201cdoor locking arrangements\u2026 where patient special needs require specialized protective measures for their safety\u2026\u201d To put such measures in place, the following must be met;\n1.\tStaff can readily unlock doors at all times in accordance with 19.2.2.2.6. \n2.\tA total (complete) smoke detection system is provided throughout the locked space in accordance with 9.6.2.9, or locked doors can be remotely unlocked at an approved, constantly attended location within the locked space. \n3.\tThe building is protected throughout by an approved, supervised automatic sprinkler system in accordance with 19.3.5.1. \n4.\tThe locks are electrical locks that fail safely so as to release upon loss of power to the device. \n5.\tThe locks release by independent activation of each of the following: \n(b)\tActivation of the smoke detection system required by 19.2.2.2.5.2(a)\n \n(b)\tWaterflow in the automatic sprinkler system required by 19.2.2.2.5.2(3).\nAs our Executive Director noted, our Facility has a mix of residents with varying physical and mental capabilities. Many of our residents may lack capacity or have mobility issues causing extensive safety concerns if those residents gained access to an emergency-only exit unassisted, outside of an emergent situation. \u00a7 18.2.2.2.5.2 does not require that all residents meet a particular clinical threshold. Rather, this section mentions door locking \u201c\u2026where patient needs require specialized protective measures for their safety.\u201d The section identifies pediatric, maternity and emergency departments as examples of where patients might have a special need that would justify door locking. This section also does not indicate a requirement that there is no less restrictive measure available prior to instituting the designated safety measure. Given the vulnerability of the population we serve and seek to protect, the Facility has elected to put these permitted safeguards in place to meet the needs of many of our residents, as our residents\u2019 safety is central to our operations. \nIn placing the allowed door locking arrangements, the Facility has diligently complied with applicable Life Safety Codes. In an emergent situation, staff are readily able to unlock doors at all times by facility staff at the designated panic buttons. The Facility has in place a complete smoke detection system included throughout the locked space. In addition, locked doors are able to be remotely unlocked by facility staff at the designated panic buttons. The building operates a supervised automatic sprinkler system. All locks on the doors in question are electrical and therefore, upon loss of power, activation of smoke detection system or automatic sprinkler, all doors will be automatically unlocked.\n\n(The submitted plan of correction exceeds the maximum allotted space. Please reach out to the department for the full plan of correction)", "planOfCorrectionHoverText": "***UKNONWN HOVER TEXT SOURCE ****", "additionalProperties": [] } ], "additionalProperties": [], "licenseId": 24789 } ], "additionalProperties": [] } --> .vdss-page-feedback-embed { clear: both !important; width: 100% !important; max-width: 100% !important; margin: 1rem 0 !important; padding: 0 !important; border: 0 !important; background: transparent !important; box-shadow: none !important; box-sizing: border-box !important; overflow: hidden !important; } .vdss-page-feedback-embed, .vdss-page-feedback-embed * { box-sizing: border-box !important; } .vdss-page-feedback-embed::before, .vdss-page-feedback-embed::after { display: none !important; content: none !important; } .vdss-page-feedback-embed__inner { width: 100% !important; max-width: 760px !important; margin: 0 auto !important; padding: 0 !important; border: 0 !important; background: transparent !important; box-shadow: none !important; overflow: hidden !important; } .vdss-page-feedback-embed__iframe { display: block !important; width: 100% !important; max-width: 100% !important; height: 360px; min-height: 185px; border: 0 !important; outline: 0 !important; background: transparent !important; box-shadow: none !important; overflow: hidden !important; transition: height 0.2s ease; } @media (max-width: 640px) { .vdss-page-feedback-embed__iframe { min-height: 245px; } } (function () { var surveyBaseUrl = "https://vdss.iad1.qualtrics.com/jfe/form/SV_6PTizOj3GJtmLie"; var iframe = document.getElementById("vdssQualtricsFeedback"); if (!iframe) return; var params = new URLSearchParams({ PageURL: window.location.href, PageTitle: document.title, PagePath: window.location.pathname }); iframe.src = surveyBaseUrl + "?" + params.toString(); window.addEventListener("message", function (event) { if (!event.data || event.data.type !== "vdssQualtricsResize") return; var newHeight = parseInt(event.data.height, 10); var minHeight = 185; var maxHeight = 430; if (!isNaN(newHeight) && newHeight > 100) { var safeHeight = Math.min(Math.max(newHeight + 30, minHeight), maxHeight); iframe.style.height = safeHeight + "px"; } }); })(); This website uses cookies to enhance your browsing experience. By continuing to use our website, you agree to our use of cookies. Please review our web policy for information regarding the data we collect and how we ensure it remains secure. Accept All Accept Necessary Virginia Department of Social Services © About Careers Mission About Us Media Information Research and Reports Transparency Civil Rights F reedom of Information Act Privacy Web Policy Accessibility Get Help 2-1-1 Virginia CommonHelp Contact Us Technical Support TTY/TDD Follow us on social Find my local department back to top let staff_directory = document.querySelector('.staff-directory'); const toggleStaffFilter = ()=> { let toggle_staff_filter_btn = document.querySelector('.staff-directory .btn-filter-results'); let staff_filter_dropdown = document.querySelector('.staff-filter'); toggle_staff_filter_btn.addEventListener('click', (e)=> { e.currentTarget.classList.toggle('btn-filter-results--active'); staff_filter_dropdown.classList.toggle('staff-filter--collapse'); }); } if (staff_directory) { toggleStaffFilter(); }
Quoted from the official DSS inspection page, pulled November 19, 2026 (America/New_York). Full official narrative: https://www.dss.virginia.gov/licensed-care/search-licensing-programs/assisted-living-facility-search/?action=inspection&licenseId=24789&inspectionNumber=38576&endpoint=alf. Longer case evidence text is left on the official page.
All official details
| Facility type | Assisted Living Facility |
|---|---|
| License ID (DSS) | 24789 |
| License facility ID | 1081431 |
| Licensed (official search flag) | Yes |
| License type | 1YR |
| Expiration date | December 25, 2026 |
| Capacity | 227 |
| Qualifications | Non-Ambulatory, Assisted Living, Special Care Un |
| Administrator | Pandora Wilson |
| Licensing inspector | Alexandra Roberts |
| Inspector phone | (804) 845-6956 |
| Address | 7470 Spring Village Dr, SPRINGFIELD, VA 22150 |
| Phone | 703-923-4649 |
| Locality | Fairfax County |
| Business hours | Sunday to Saturday 24 hours a day |
Source: https://www.dss.virginia.gov/licensed-care/search-licensing-programs/assisted-living-facility-search/?licenseId=24789&endpoint=alf (Virginia Department of Social Services licensed-care search), pulled November 19, 2026 (America/New_York). Confirm current license status on the official page.
Other licensed providers in Fairfax County
Listed alphabetically from official records. See all in Fairfax County